Customization: | Available |
---|---|
Type: | Water-Cooled |
Cooling Method: | Water-cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The Details of the chiller:
1.The Temperature Range:7ºC to -85ºC.
2.Cooling Capacity Range:
1RT to 1000RT
3.52kw to 3520kw
12010Btu to 12010240Btu
3027.2Kal to 3027200Kal
3. The Refrigerant: R22/R407c/R410a/R404a/R134a/R507c.
4.We can also produce the chiller according to your requirements.
One Parameter of our water chiller:
Air-cooled chiller parameters(output tem 7ºC)
Model | UNIT | WD- | ||||||||||
3AC/S | 5AC/S | 8AC/S | 10AC/S | 12AC/S | 15AC/S | 20AC/S | 25AC/S | 30AC/S | 40AC/S | |||
Cooling capacity | Btu | 30026 | 49133 | 87006 | 98948 | 111572 | 140233.2 | 188684 | 223145 | 280466 | 377367 | |
RT | 2.5 | 4.1 | 7.2 | 8.3 | 9.3 | 11.7 | 15.7 | 18.6 | 23.4 | 31.5 | ||
Kw | 8.8 | 14.4 | 25.5 | 29.0 | 32.7 | 41.1 | 55.3 | 65.4 | 82.2 | 110.6 | ||
×10³Kcal/h | 7.6 | 12.4 | 21.9 | 25.0 | 28.1 | 35.4 | 47.6 | 56.3 | 70.7 | 95.2 | ||
Total Power | KW | 3.1 | 5.2 | 8.1 | 9.5 | 10.9 | 14.4 | 19.3 | 20.5 | 28.6 | 38.0 | |
Total Current | A | 5.7 | 9.6 | 14.8 | 17.3 | 19.9 | 26.3 | 35.3 | 37.6 | 52.3 | 69.5 | |
Compressor | Qty | set | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 2.00 | 2.00 | 2.00 |
Input power | kw | 2.6 | 4.3 | 7.0 | 7.9 | 8.9 | 12.4 | 16.6 | 17.9 | 24.9 | 33.3 | |
Operation Current | A | 4.6 | 7.6 | 12.4 | 14.0 | 15.9 | 22.1 | 29.6 | 31.8 | 44.3 | 59.2 | |
Condenser | Type | Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger | ||||||||||
Fans | Input power | kw | 0.19 | 0.42 | 0.38 | 0.84 | 0.84 | 0.84 | 1.14 | 1.14 | 1.50 | 2.52 |
Input Current |
A | 0.50 | 0.85" | 1.00 | 1.70" | 1.70 | 1.70 | 3.00 | 3.00 | 3.84 | 5.10" | |
Evaporator | Type | Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger | ||||||||||
Freezing water Flow | L/min | 25 | 41 | 73 | 83 | 93 | 118 | 158 | 187 | 235 | 316 | |
Water pipe connection | mm | 25" | 25 | 32 | 32 | 32 | 40 | 40" | 50 | 50 | 65" | |
Freezing Water Pump | Type | High efficiency, low noise | ||||||||||
Input Power | Kw | 0.37 | 0.55 | 0.75 | 0.75 | 1.10 | 1.10 | 1.50 | 1.50 | 2.20 | 2.20 | |
Head | m | 16 | 21 | 22 | 19 | 17 | 25 | 24 | 23 | 22 | 21 | |
Refrigerant | Type | R22/R134A/R407C/R410A/R507/R404 | ||||||||||
Water tank Indicating Volume | Liter | 70 | 75 | 100 | 115 | 145 | 250 | 270 | 320 | 360 | 400 | |
Safety protection | high and low pressure protection, overload protection, over temperature protection, phase sequence protection, etc. | |||||||||||
Dimensions (L*W*H) | Length | mm | 1150 | 1150 | 1200 | 1350 | 1400 | 1600 | 1950 | 2100 | 2200 | 2450 |
Width | mm | 560 | 560 | 850 | 850 | 850 | 1000 | 1250 | 1250 | 1250 | 1350 | |
High | mm | 1120 | 1120 | 1550 | 1550 | 1550 | 1600 | 1600 | 1600 | 1850 | 2050 | |
Total Weight | KG | 150 | 200' | 285 | 350' | 450 | 600 | 830 | 1050 | 1250 | 1350 |
Note:
1, the table refrigeration conditions: cold water inlet temperature 12 ºC, cold water temperature 7 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, crew safe operating range: Chilled water inlet temperature 9 ~ 20 ºC;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa)
6, In addition to the specifications and requirements, we can provide non-standard products according to customer requirements.